The heat conductivity of the gas mixture is calculated as

\begin{equation*}
{\overline \lambda} = \sum_{i}^{N}
x_{i} \, \lambda_{i}
\end{equation*}

Nomenclature

\(\lambda_{i}\) heat conductivity of species Ai
\(x_{i}\) mole fraction of species Ai